Rigid limb surrogates transfer full mechanical loads directly to the prosthetic socket during structural testing, causing premature distal failure and underestimating of actual load capacity. In contrast, soft-compliant surrogates buffer applied loads and enables realistic structural deformation. This study investigates: (i) the influence of rigid Plaster of Paris (PoP) versus biofidelic hyperelastic silicone surrogates on the structural load capacity of 3D-printed transfemoral prosthetic sockets; and (ii) orientation-dependent structural deformation and failure behaviors arising from asymmetric transfemoral anatomy. Sockets encapsulated with PoP and silicone surrogates were evaluated under ISO 10328:2016 static loading (Condition II) at two loading alignments: toe-off and toe-towards-lateral (90° laterally rotated) configurations. Initial testing with 3D-printed Bespoke Commercial (BC) connectors induced premature distal connector failure; however, under toe-towards-lateral loading, socket/silicone assemblies exhibited a 4.47-fold greater displacement and a 72.46% higher ultimate force than socket/PoP assemblies. Sockets with an enlarged BC connector encapsulated in the silicone surrogate showed distinct force-displacement hysteresis loops under toe-towards-lateral loading, indicating energy dissipation. Crucially, enlarging the BC connector shifted the failure site from interlayer delamination at the distal end under toe-off to trans-layer fracture across the lateral socket wall. Conversely, socket/PoP assemblies consistently failed at the enlarged BC distal connector regardless of loading orientation. Finite element analysis (FEA) confirmed non-compliant, uniform contact pressure in socket/PoP assemblies, whereas the silicone surrogate produced compliant pressure gradients. Loading orientation significantly affected the structural deformation (p < 0.05) of socket/silicone assemblies: toe-towards-lateral loading induced two-fold greater deformation and an 18.95% higher ultimate force than under toe-off loading due to the thicker lateral silicone resulting from asymmetric limb geometry. These findings demonstrate that a biofidelic hyperelastic surrogate buffers stress and redistributes contact pressure similar to biological soft tissue, establishing a more accurate pre-clinical framework for evaluating 3D-printed prosthetic socket strength.
เหตุผลที่อยู่ในฐานติดตาม
ระเบียนนี้ได้รับ Impact Signal 70/100 จากความใหม่ แหล่งเผยแพร่ ความร่วมมือ และสัญญาณในข้อมูลบรรณานุกรม คะแนนนี้ใช้จัดลำดับการติดตาม ไม่ใช่การตัดสินคุณภาพงานวิจัย
ประเด็นที่เกี่ยวข้อง: Prosthetics and Rehabilitation Robotics · Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty
บทบาทของนักวิจัยและสถาบันไทย
Pimpet Sratong-on · Onanong Sukjai · Sawanya Suwannawong · Kazuhiko Sasaki · Thai-Nichi Institute of Technology · Mahidol University
ข้อจำกัดของข้อมูล
หน้านี้เป็นระเบียนบรรณานุกรมและข้อมูลจากบทคัดย่อ ยังไม่ใช่บทวิเคราะห์ฉบับเต็มหรือการประเมินคุณภาพงานวิจัย ควรตรวจสอบ DOI และเอกสารต้นฉบับก่อนนำไปอ้างอิง